26/03/2018 at 10 h 51 min
#6176
Service Technique
Participant
Dear,
To our knowledge, the MorphoAccess Sigma Extreme Biometric Reader is not designed to resist to acid substances.
What is certain is that it hasn’t been certified for these environnements.
However, the MA Sigma Extreme is certified on many other aspects:
• Shock resistance: IK09
• Waterproof: IP65
• Temperature: -20 ° C to 60 ° C
• Humidity: 10% to 95% (non condensing)
• EMC / Safety Certifications: CE, CB, FCC and RoHS compliant, REACh and WEEE.
The advantages of this reader are:
• Ultra-resistant shells
• Hard Plastics (Polycarbonate PC)
• Minimum thickness of 3.5 mm
• Resistant to UV and climate aging (UL 746C f1 standard)
• Dust-proof grained texture